Sample cut horizontally, normal testing cannot be done. Woof: 8.6
Dry particle Filtration Efficiency
ASTM F 2299
No Particle Penetration
Wet Particle Filtration Efficiency
ASTM F 2299
No Particle Penetration
Anti-Static; Surface Resistivity
BS EN 1149-1:2006
1.2 x 10⁹ Ω
Air Permeability (cfm)
ASTM D737
<0.55
Burst Strength (lbs)
ASTM D3787
20
Tensile Strength (lbs) Machine Direction
ASTM D5034
23.2
Tensile Strength (lbs) Cross Direction
ASTM D5034
18.1
Tensile Strength (lbs) Trapezoidal - Machine Direction
ASTM D1117
9.76
Tensile Strength (lbs) Trapezoidal - Cross Direction
ASTM D1117
4.97
Chemical permeation resistance
Agent
Test method
Penetration
Repellency
Bleach 5%
ASTM T903
Pass
—
Hydraulic Jack Oil
ASTM T903
Pass
—
Isocyanate Based Paint Hardener
ASTM T903
Pass
—
Motor Oil
ASTM T903
Pass
—
Sodium hydroxide
ASTM T903
Pass
—
Mineral Oil
ASTM T903
Pass
—
Blood
ASTM F1670-07
Pass
—
Add overhead work to a dusty job — spraying ceilings, demo, fiber abatement — and a collar-style suit leaves hair and neck exposed. The hooded 8015 closes that gap: an attached hood sized to fit over respirators and head coverings, with elastic wrists and ankles that seal the suit at every opening.
Underneath is the same MicroGuard MP microporous laminate — a liquid and particulate barrier rated against blood penetration (ASTM F1670) — so one suit covers painting crews and biohazard response alike.
Why crews pick it
High moisture-vapor transmission lets sweat escape, so hooded coverage doesn't turn into heat stress
Tougher against tears and abrasion than standard polypropylene, it survives ladders and tight spaces
Head-to-ankle seal means less decon time and fewer contaminated clothes going home